• Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110
  • Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110
  • Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110

Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110

Brand: Testo
Customized: Non-Customized
Portable: Portable
Certification: CE
Gas: CO
Type: Electrochemical Gas Analyzer
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (13)

Basic Info.

Model NO.
Testo 310
Product Name
Flue Gas Analyzer
Model Number
Testo 310
Order Number
0563 3110
Operating Temperature
-5 to +45 °c
Display Type
LCD
Display Function
Backlit 2-Line Display
Power Supply
Battery: 1500 mAh, Mains Unit 5V/1A
Storage Temperature
-20 to +50 °c
Transport Package
One Piece/Box
Specification
201 x 83 x 44 mm
Trademark
Testo
Origin
Germany
HS Code
9030311000
Production Capacity
10000PCS/Year

Product Description

Original Testo 310 set  flue gas analyzer With printer No.0563 3110

Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110


Feature

  • Robust and light instrument for daily use

  • 30 seconds sensor zeroing

  • Integrated condensate trap

  • Integrated magnets for easy fixing to burner

testo 310 incl. battery and calibration protocol for the measurement of O2, CO, hPa and °C; IR printer (0554 3100); probe 180 mm with cone; case; mains unit incl. cable; silicon hose for pressure measurement; particle filter 5 off; 2 rolls spare thermal paper for printer.

Product Description

The testo 310 has two measurement cells for O2 and CO, and a temperature sensor integrated into the flue gas probe. The gas sensors measure the exact oxygen and carbon monoxide content as well as the flue gas and ambient temperature. From these data, all relevant measurement parameters such as CO2 value, degree of effectivity and flue gas loss are calculated. The instrument stands out thanks to its easy handling and simple menu structure. You can read off the measurement values confidently and conveniently from the well-lit display, even in bad light conditions. The fuels are stored not just as numbers, but are each described. At the top edge of the clear display, the symbols for the different measurement menus are always in view. The display and the dirt-insensitive keypad are clearly structured. Operation is very easy - even if you only have one hand free.

Applications:

• Flue gas measurement

• Draught measurement

• Ambient CO measurement


• Pressure measurement


Technical Data:
 

Temperature - TC Type K (NiCr-Ni)

Measuring range

-20 to +100 °C

Accuracy

±1 °C

Resolution

0.1 °C

Reaction time

< 50 s

Temperature (ambient temperature)

Temperature - TC Type J (Fe-CuNi)

Measuring range

0 to +400 °C

Accuracy

±1 °C (0 to +100 °C)

±1.5 % of mv (> 100 °C)

Resolution

0.1 °C

Reaction time

< 50 s

Temperature (flue gas)

Flue gas O2

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t90

30 s

Flue gas Draught

Measuring range

-20 to +20 hPa

Accuracy

±0.03 hPa (-3.00 to +3.00 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.01 hPa

Flue gas degree of effectivity, Eta (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue gas CO2 calculation (calculated from O2)

Measuring range

0 to CO2 max (Display range)

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t90

< 40 s

Pressure measurement

Measuring range

-40 to +40 hPa

Accuracy

±0.5 hPa

Resolution

0.1 hPa

Flue gas CO (without H2-compensation)

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time t90

60 s

Ambient CO

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time

60 s

General technical data

Dimensions

201 x 83 x 44 mm

Operating temperature

-5 to +45 °C

Display type

LCD

Display function

Backlit 2-line display

Power supply

Battery: 1500 mAh, mains unit 5V/1A

Storage temperature

-20 to +50 °C

Weight

(with probe) Approx. 700 g


Product Photos:
Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110
Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110
Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110

Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110

FAQ

1.   Where is your company?

we are located in Guangzhou, the capital city of Guangdong Province, near to Shenzhen, Foshan & Hong Kong, very convenient for shipping.

2.  How about the MOQ?

1 unit is ok.

3.  Shipping methods and lead time?

By Express: 5-7 working days to your door (DHL, UPS, TNT, FedEx...).

By Air: 7-10 working days to your airport.

By Sea: Pls advise your port of destination, the exact days will be confirmed by our forwarders, and the following lead time is for your reference.Europe and America (25 - 35 days), Asia (3-7 days), Australia ( 16-23 days).
 

4.  What is the term of Payment?

T/T, L/C,Western Union, Paypal;  

30% T/T in advance,70% before delivery.
 

5.  What are your main products?

Compressor;

Refrigeration gas;

Refrigeration spare parts ;

Cold room panels and equipments .
 

6.  Packaging & Shipping:

Packing: wooden pallet, wooden case or with outer carton, or as per customers' specific requirements.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2017

Suppliers with verified business licenses

Trading Company
Number of Employees
4
Year of Establishment
2016-08-09