Feature
Six applications, one device: flue gas, flue draft, pressure, gas leak detection, CO ambient air and pressure difference measurements
Integrated flue gas sensors with temperature sensor included; ultra-fine pressure sensors and a wide range of other sensors, ports and probes optional
Rugged, high-quality design, high-resolution, multi-color display, self-explanatory menu guide
TÜV-tested according to EN 50379, Parts 1-3 and 1st BImSchV
Temperature measurements at radiators; flue gas parameter and pressure measurements at burners; CO measurements in the ambient air: the testo 320 allows you to carry out all measurements in and around heating systems with only one measuring device.
Product Description
The testo 320 High Efficiency Flue Gas Analyzer is a reliable measurement tool for installation, testing and maintenance of heating systems. The high-quality, professional design and easy-to-use features of the testo 320 High-Efficiency Flue Gas Analyzer help you to perform all heating-related parameters measurements from one instrument. The rugged enclosure of the testo 320 High Efficiency Flue Gas Analyzer is specifically designed for everyday use in harsh environments.
Well-structured measurement menus, designed according to different countries and built-in menu programs effectively simplify the operation. All readings are displayed on a high resolution color display that can be used in a variety of lighting situations. The testo 320 High Efficiency Flue Gas Analyzer also has a memory with 500 readings.
Testo 320 Efficient Flue Gas Analyzer - Instrument Features
The testo 320 high-efficiency flue gas analyzer is equipped with 1 flue gas sensor - one is an O2 sensor, and the other is a CO sensor. At the same time, there is a combustion air temperature sensor at the bottom of the instrument, and a thermocouple signal interface is integrated in the flue gas sampling probe interface. This helps you achieve simultaneous measurement of temperature, oxygen and carbon monoxide as well as other various parameters.
The portable flue gas analyzer also automatically calculates relevant flue gas parameters such as CO2 value, boiler combustion efficiency, and flue gas loss.
At the same time, there are plenty of different sensors and probes available for your choice. Including porous probes, flexible flue gas probes and precision pressure probes. This precise pressure probe helps you to measure the smoke pumping force and differential pressure synchronously with other parameters
Testo 320 flue gas analyzer application
Six applications. One instrument:
(1)Smoke measurement
(2)Smoke extraction measurement
(3)Flue gas flow rate and static pressure measurement
(4)Flammable gas leak detection
(5)Environmental CO Measurement
(6)Temperature difference measurement
Helps you quickly and safely monitor and detect heating units, radiators, and burners
Testo 320 flue gas analyzer, O2 sensor and high quality instrument box.
Choose you need model:
Different | Measuring range | Accuracy (± 1 digit) | Resolution | Adjustment time t90 |
|
Testo 320 Set 1 (0563 322070) |
CO measurement (without H2-compensation) |
0 to 4 000 ppm |
±20 ppm (0 to 400 ppm) (401 to 2 000 ppm) (2 001 to 4 000 ppm) |
1 ppm | < 60 sec |
Testo 320 Set 2 (0563 322075) |
CO measurement (H2-compensated) |
0 to 8 000 ppm |
±10 ppm or ±10 % of m.v. (0 to 200 ppm) (201 to 2 000 ppm) (2 001 to 8 000 ppm) |
1 ppm | < 40 sec |
Testo 320 Set 1 (0563 322070) |
Option COlow measurement (H2-compensated) |
0 to 500 ppm |
±2 ppm (0 to 39.9 ppm) (remaining meas. range) |
0.1 ppm | < 40 sec |
Testo 320 Set 2 (0563 322075) |
Ambient CO measurement (with CO probe) |
0 to 500 ppm | ±5 ppm (0 to 100 ppm) ±5 % of m.v. (> 100 ppm) |
1 ppm |
Measuring range | Accuracy (± 1 digit) | Resolution | Adjustment time t90 |
|
Temperature | -40 to +1 200 °C | ±0.5 °C (0 to +100.0 °C) ±0.5 % of m.v. (remaining meas. range) |
±0.1 °C (-40 - +999.9 °C) |
|
Draught measurement |
-9.99 to +40 hPa |
±0.02 hPa or ± 5 % of m.v. (-0.50 to +0.60 hPa) |
0.01 hPa draught option |
|
Pressure measurement |
0 to +300 hPa | ±0.5 hPa (0.0 to +50.0 hPa) ±1 % of m.v. (+50.1 to +100.0 hPa) ±1.5 % of m.v. (remaining meas. range) |
0.1 hPa draught option |
|
O2 measurement | 0 to 21 vol.% | ±0.2 vol.% | 0.1 vol.% | < 20 sec |
CO measurement (without H2-compensation) |
0 to 4 000 ppm | ±20 ppm (0 to 400 ppm) ±5 % of m.v. (401 to 2 000 ppm) ±10 % of m.v. (2 001 to 4 000 ppm) |
1 ppm | < 60 sec |
CO measurement (H2-compensated) |
0 to 8 000 ppm |
±10 ppm or ±10 % of m.v. (0 to 200 ppm) (201 to 2 000 ppm) (2 001 to 8 000 ppm) |
1 ppm | < 40 sec |
Efficiency testing (Eta) |
0 to 120% | 0.10% | ||
Flue gas loss | 0 to 99.9% | 0.10% | ||
CO2 determination digital calculation from O2 |
Display area 0 to CO2 max |
±0.2 vol.% | 0.1 vol.% | < 40 sec |
Option COlow measurement (H2-compensated) |
0 to 500 ppm |
±2 ppm (0 to 39.9 ppm) (remaining meas. range) |
0.1 ppm | < 40 sec |
Ambient CO measurement (with CO probe) |
0 to 500 ppm | ±5 ppm (0 to 100 ppm) ±5 % of m.v. (> 100 ppm) |
1 ppm | |
Gas leak measurement for combustible gases (with gas leak detector probe) |
Display area 0 to 10 000 ppm CH4 / C3H8 |
Signal visual indication (LED) audible indication by buzzer |
||
Ambient CO2 measurement (with ambient CO2 probe) |
0 to 1 vol.% 0 to 10 000 ppm |
± 50 ppm or ± 2 % of meas. val. (0 to 5 000 ppm) |
< 2 sec | |
Differential pressure, flow velocity and temperature via fine pressure probe |
±10 000 Pa +1 200 °C |
±0.3 Pa (0 to 9.99 Pa) plus ±1 digit plus ±1 digit (remaining meas. range) |
0.1 m/s 0.1 °C |
1. Where is your company?
we are located in Guangzhou, the capital city of Guangdong Province, near to Shenzhen, Foshan & Hong Kong, very convenient for shipping.
2. How about the MOQ?
1 unit is ok.
3. Shipping methods and lead time?
By Express: 5-7 working days to your door (DHL, UPS, TNT, FedEx...).
By Air: 7-10 working days to your airport.
By Sea: Pls advise your port of destination, the exact days will be confirmed by our forwarders, and the following lead time is for your reference.Europe and America (25 - 35 days), Asia (3-7 days), Australia ( 16-23 days).
4. What is the term of Payment?
T/T, L/C,Western Union, Paypal;
30% T/T in advance,70% before delivery.
5. What are your main products?
Compressor;
Refrigeration gas;
Refrigeration spare parts ;
Cold room panels and equipments .
6. Packaging & Shipping:
Packing: wooden pallet, wooden case or with outer carton, or as per customers' specific requirements.