Basic Info.
Range Conversion Type
MAN RANGZ
Additional Measuring Item
Capacitance
Product Name
Digital Multimeter
DC Voltage
200.0 Mv, 2.000 V, 20.00 V, 200.0 V, 1500 V
AC Voltage
200.0 Mv, 2.000 V, 20.00 V, 200.0 V, 1000 V
Current
AC/DC 200.0 µa, 2.000 Ma, 20.00 Ma, 200.0 Ma
Resistance
200.0 O, 2.000 Ko, 20.00 Ko, 200.0 Ko, 2.000 Mo, 2
Transport Package
One Piece/Box
Specification
200 x 102 x 59 mm
Product Description
1500V DC HD110C Amprobe Heavy-Duty Digital MultimeterFeature
- Highest voltage capability, measuring to 1500 V DC and 1000 V AC
- CAT IV 1000 V rated
- Special sealing for environment and water resistance: IP67 rated
- Constructed with drop-resistant housing and PCB mounting
- Magne-Grip™ holster, frees both hands for work
- Includes high voltage test leads with threaded alligator clips
- Display 3-1/2 digit LCD, 1999 counts, with annunciators
- Automatic polarity indication
- Low battery indication
- Standard 9 V battery, NEDA 1604, JIS 006P,IEC 6F2
- Flame retardant, high-impact thermoplastic case
- Resistance ranges 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ
Product Description
The Amprobe HD110C Heavy Duty Multimeter is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. Its made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts.
Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistant to at least eight feet. The HD110C has an extended voltage measurement capability of 1500 V DC and 1000 V AC, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kV.
Delivery Scope
- HD110C
- Test leads
- Batteries (installed)
- Magne-Grip™ holder with magnetic hanging strap
Specifications
| FEATURE | HD110C | HD160C |
| DC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1500 V | 1000.0 mV, 10.000 V, 100.00 V, 1500.0 V |
| AC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1000 V | 1000.0 mV, 10.000 V, 100.00 V, 1000.0 V |
| Current | AC/DC 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA, 2 A | 100.00 µA, 1000.0 µA, 10.000 mA, 100.00 mA, 400.0 mA, 2.000 A |
| Resistance | 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO | 1000.0 O, 10.00 kO, 100.00 kO, 1000.0 kO, 10.000 MO, 40.00 MO |
| Diode | • | - |
| Continuity | • |
| Frequency | - | 100.00 Hz, 1000.0 Hz, 10.000 kHz, 100.00 kHz, 1000.0 kHz, 10.000 M Hz |
| Capacitance | - | 40.00 nF, 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF |
| Temperature | - | -4 °F → 2372 °F (-20 °C → 1300°C) |
| True-rms | - | • |
| Specifications |
| DC Volts range: | 200 mV, 2 V, 20 V, 200 V, 1500 V |
| DC Volts resolution: | 0.1 mV |
| DC Volts accuracy: | All ranges ±(0.1 % rdg+2 dgts) |
| DC Volts input impedance: | 10 MO |
| DC Volts OL protection: | >1500 V DC/1000 V AC rms |
| DC Volts transient protection: | >12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV |
| AC Volts (45 Hz to 2 kHz) ranges: | 200 mV, 2 V, 20 V, 200 V, 1000 V |
| AC Volts (45 Hz to 2 kHz) resolution: | 0.1 mV |
| AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts), |
| AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts) |
| AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts) |
| AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts) |
| AC Volts (45 Hz to 2 kHz) input impedance: | 10 MO |
| AC Volts (45 Hz to 2 kHz) OL protection: | 1500 V DC/1000 V AC rms |
| AC Volts (45 Hz to 2 kHz) transient protection: | 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV. |
| DC Current range: | 200 µA, 2 mA, 20 mA, 200 mA, 2 A |
| DC Current resolution: | 0.1 µA |
| DC Current accuracy: | 200 µA to 20 mA ±(0.5 % rdg+2 dgts) |
| DC Current accuracy: | 200 mA to 2 A ±(1.0 % rdg+2 dgts) |
Product Photos
FAQ1. Where is your company?
we are located in Guangzhou, the capital city of Guangdong Province, near to Shenzhen, Foshan & Hong Kong, very convenient for shipping.
2. How about the MOQ?
1 unit is ok.
3. Shipping methods and lead time?
By Express: 5-7 working days to your door (DHL, UPS, TNT, FedEx...).
By Air: 7-10 working days to your airport.
By Sea: Pls advise your port of destination, the exact days will be confirmed by our forwarders, and the following lead time is for your reference.Europe and America (25 - 35 days), Asia (3-7 days), Australia ( 16-23 days).
4. What is the term of Payment?
T/T, L/C,Western Union, Paypal;
30% T/T in advance,70% before delivery.
5. What are your main products?
Compressor;
Refrigeration gas;
Refrigeration spare parts ;
Cold room panels and equipments .
6. Packaging & Shipping:
Packing: wooden pallet, wooden case or with outer carton, or as per customers' specific requirements.
Address:
410 Room, Dashun Business Center, No. 777, Zhongshan Road West, Tianhe District, Guangzhou, Guangdong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery
Company Introduction:
Our company is specialized in refrigeration equipment production and sales, also we are agent for many brands compressors, refrigerants &refrigeration accessories, with reliable quality and service. At the same time, we can provide export transportation, export & custom clearance services, etc.
We are looking forward to providing our esteemed customers with one-stop sourcing experience.