Customization: | Available |
---|---|
Warranty: | One Year Guarantee |
Brand: | Fluke |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Use Fluke Connect Measurements to connect the meter to your smartphone
Read
the measured value through the mobile phone at a safe distance, the
meter assumes all risks, and the staff only needs to wear less personal
protective equipment
Record measurement results directly to mobile phone and Cloud
Use the logging function of Fluke 376 FC to perform other tasks while collecting intermittent faults
Create reports on site and share them instantly via email, or use ShareLive™ video calls for real-time conversations
The
iFlex flexible current probe expands the measurement range of AC
current to 2500 A; it can be measured in a small space with a large-size
conductor (included)
TPAK magnetic lanyard (included)
The integrated VFD low-pass filter can be used to accurately measure the drive motor
Using
proprietary surge measurement technology, it can filter out noise and
accurately capture motor starting current through current protection
monitoring
CAT IV 600 V, CAT III 1000 V safety level
come with Soft carrying case
1000 A AC and DC current measurement
2500 A AC current measurement (using iFlex flexible current probe)
1000 V AC and DC voltage measurement
Can accurately measure the true RMS voltage and current of nonlinear signals
Use the main clamp and iFlex to perform frequency measurements up to 500 Hz
Resistance measurement can reach 60 kΩ, and continuity detection is possible
The minimum, maximum, average and surge recording functions can automatically collect the reading changes
With other accessories, it can perform 500 mV DC measurement
1000 μF capacitance measurement
General technical specifications |
||
AC current through the clamp |
||
Range |
999.9 A |
|
Resolution |
0.1 A |
|
Accuracy |
2% ± 5 digt(10 Hz to 100 Hz) |
|
2.5% ±5 digt (100-500 Hz) |
||
Crest factor (50 Hz/60 Hz) |
3(500 A ) |
|
2.5(600 A ) |
||
Increase by 2% when C.F.> 2 |
AC current through flexible current probe |
||
Range |
2500 A |
|
Resolution |
0.1 A (≤ 600 A) |
|
1 A (≤ 2500 A) |
||
Accuracy |
3% ±5 (5 - 500 Hz) |
|
Crest factor (50/60Hz) |
3.0(1100 A ) |
|
2.5(1400 A ) |
||
1.42(2500 A ) |
||
Increase by 2% when C.F.> 2 |
DC Current |
||
Range |
999.9 A |
|
Resolution |
0.1 A |
|
Accuracy |
2% ± 5 digt |
|
AC Voltage |
||
Range |
1000 V |
|
Resolution |
0.1 V (≤600.0 V) |
|
1 V (≤1000 V) |
||
Accuracy |
1.5% ± 5 digt(20 Hz to 500 Hz) |
|
DC Voltage |
||
Range |
1000 V |
|
Resolution |
0.1 V (≤600.0 V) |
|
1 V (≤1000 V) |
||
Accuracy |
1% ± 5 digt |
|
mV DV |
||
Range |
500.0 mV |
|
Resolution |
0.1 mV |
|
Accuracy |
1% ± 5 digt |
|
HZ(Through Clamp) |
||
Range |
5.0 Hz to 500.0 Hz |
|
Resolution |
0.1 Hz |
|
Accuracy |
0.5% ± 5 digt |
|
Trigger level |
5 Hz to 10 Hz,≥10 A |
|
10 Hz to 100 Hz,≥5 A |
||
100 Hz to 500 Hz,≥10 A |
||
Hz (via flexible current probe) |
||
Range |
5.0 Hz to 500.0 Hz |
|
Resolution |
0.1 Hz |
|
Accuracy |
0.5% ± 5 digt |
|
Trigger level |
5 Hz to 20 Hz,≥25 A |
|
20 Hz to 100 Hz,≥20 A |
||
100 Hz to 500 Hz,≥25 A |
||
Resistance |
||
Range |
60 kΩ |
|
Resolution |
0.1 Ω (≤600 Ω) |
|
1 Ω (≤6000 Ω) |
||
10 Ω (≤60 kΩ) |
||
Accuracy |
1% ± 5 digt |
|
Capacitance |
||
Range |
1000 μF |
|
Resolution |
0.1 μF (≤ 100 μF) |
|
1 μ F (≤ 1000 μF) |
||
Accuracy |
1% ± 4 |
|
Mechanical specifications |
||
Highest voltage between any terminal and ground |
1000 V |
|
Battery |
2 AA,NEDA 15A,IEC LR6(Not Included) |
|
Work Temperature |
-10 °C to +50 °C |
|
Storage temperature |
-40 °C to +60 °C |
|
Working humidity - Non-condensing (< 10 °C) |
≤90% RH(10 °C to 30 °C) |
|
≤75% RH(30 °C to 40 °C) |
||
≤45% RH(40 °C to 50 °C) |
||
Working altitude |
2000 m |
|
Storage altitude |
12000 m |
|
Size |
249 x 85 x 45 mm |
|
Weight |
395 g |
|
Jaw Open |
34 mm |
|
Flexible current probe diameter |
7.5 mm |
|
Flexible current probe cable length (End to wire connector) |
1.8 m |
|
Safety Degree |
IEC 61010-1,Pollution degree 2 |
|
IEC 61010-2-032:CAT III 1000 V / CAT IV 600 V |
||
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V |
||
IP Protection level |
IEC 60529:IP30 |
|
FCC ID |
T68-FBLE IC:6627A-FBLE |
The Fluke 376 FC True-rms Clamp Meter combines functionality with form to create a powerful troubleshooting clamp that is easy to handle. The Fluke 370FC Series offers the only clamp meters in the market to offer a flexible current probe, logging and safe remote measurements, all in one tool.
18-inch iFlex® Flexible Current Probe
TPAK magnetic hanging strap
Soft carrying case
TL75 test leads
Coated instruction card
Safety information sheet
The Fluke 376 FC is part of the Fluke Connect family of wireless test tools.
Now you can:
Log and trend measurements to pinpoint intermittent faults
Transmit results wirelessly via Fluke Connect® Measurements app
Create and send reports right from the field
Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices
The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter.
Connect your meter to your smartphone with Fluke Connect Measurements
Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
Record results directly to your phone and the Cloud
Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
TPAK magnetic hanging strap (included)
Integrated VFD low pass filter for accurate motor drive measurements
Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
CAT IV 600 V, CAT III 1000 V safety rating
Three-year warranty
Soft carrying case
Measurement Capability
1000 A ac and dc current measurement
2500 A ac current measurement with iFlex flexible current probe
1000 V ac and dc voltage measurement
True-rms voltage and current for accurate measurements on non-linear signals
Frequency measurement to 500 Hz with body jaw and iFlex
Resistance measurement to 60 k with continuity detection
Min, max, average, and inrush recording to capture variations automatically
500 mV dc measurement range to interface with other accessories
1000 μF capacitance measurement